North America

Vector Smart Object

IDEXX BioAnalytics now provides high quality LC-MS/MS bioanalysis 
for small molecule compounds. In addition to standard protein 
precipitation, IDEXX BioAnalytics offers solid phase extraction and 
solid supported liquid extraction.

We offer the same high-quality, flexible, and fast turnaround in our bioanalysis laboratory as we do for our current clinical and anatomic pathology services.

Analytical Equipment

 

• Sciex 5500+ Triple Quadrupole Mass Spectrometer
    – ESI source and APCI source
• Shimadzu Nexera X2 HPLC
• Integra Biosciences VIAFLO96 pipetting robot
• Beckman Avanti JXN-26 refrigerated centrifuge
• Mettler XPR36DR analytical balance
• Biotage TurboVap96 evaporator
• WinNonlin Phoenix software

Extraction Types

 

• Protein precipitation
    – Organic and acidic methods
• Solid Phase Extraction
• Solid Supported Liquid Extraction

Sample Types We Work With

  • Blood

  • Serum

  • Urine

  • Tissue homogenates

Bioanalytical Services: Small molecule LC-MS/MS Services

Method Feasability

• Detecting the compound in the mass spectrometer
    – Compound infusion
    – Ionization parameter optimization
• Eluting the retained compound from the UHPLC column
    – Column and mobile phase selection
    – Compound injection for retention time 
       and peak shape assessment

Development and Pre-qualification
• Optimizing the LC-MS/MS method
• Accuracy
    – 3 concentrations tested
• Precision
    – 3 concentrations tested
    – Quality control samples every 10 samples
• Linearity
    – 8 concentrations tested
• Sensitivity
    – Limit of Detection

Method Qualification

Sensitivity and Linearity

• Assessment of duplicate extracted and non-extracted 
  standard curves for linearity and sensitivity and 
  reproducibility on two or three different injection days

Quality Controls

• High, medium, and low concentrations
  in duplicate

Non-GLP Sample Analysis

• Pre- and post-analysis standard curves for QC
• Interspersed QCs through samples
    – 10% of total number of samples tested
• Summary report in Excel format
    – System suitability
    – Standards & QC: Reporting of used/excluded, 
       nominal, back calculated, accuracy, coefficient 
       of variation
    – Carryover
    – Samples: Calculated concentration in tabular 
       format, graphical format optional

IDEXX BioAnalytics provides the expertise to best support your Small Molecule Bioanalysis work.

Contact IDEXX BioAnalytics today to discuss your research needs.

IDEXX uses the information provided to contact you about relevant content, products, and services at IDEXX BioAnalytics.
You may unsubscribe from these communications at any time.